Kaiyi — Kaiyi Power Train System Technical Manual

9) INSTALLATION OF INPUT SHAFT, OUT- INSTALLATION OF INPUT SHAFT, OUT- PUT SHAFT, PUMP SHAFT (POWER- PUT SHAFT, PUMP SHAFT (POWER- TAKE OFF SHAFT) AND CLUTCHES TAKE OFF SHAFT) AND CLUTCHES 1 (1) If the suction tube (1) in the housing front part is to be replaced, it is imperative to use the special tool (rolling tool) for assembly. Then fix the tube with cylindrical screw (2). (Oil cylindrical screw) It is always necessary to use new cylindrical screws. 余 Tightening torque (M8/8.8 佴 12) :

2.34 kgf 余 m (17.0 lbf 余 ft ) Rolling tool 5870 600 003 Lubricant 5870 451 006 2 侍 7609ATM306 侍 The spare parts service supplies the lubri- cating oil tube (1) only as a complete package with the housing front part. 侍 Single parts delivery upon request only. 侍 Assembly is only possible with the spe- cial tool. 1 Rolling tool 5870 600 005 Lubricant 5870 451 006 7609ATM307 (2) Mount O-rings 22 佴 3 into the annular groove of the oil tubes (1 and 2) and oil them. 3 3 Then insert tubes into the housing front part, oil cylindrical screws (3 and 4) and fix them. It is always necessary to use new cylindri- cal screws. 侍 1 2 余 Tightening torque (M8/8.8 佴 12) :

2.34 kgf 余 m (17.0 lbf 余 ft ) 余 Tightening torque (M8/8.8 佴 50) : 2.34 kgf 余 m (17.0 lbf 余 ft ) 4 4 7609ATM308 3-173