Σ Preload disk package with an axial force of F = 50 +30 kN. Then check the setting dimension "A" = 1.05 佳 0.1 mm from the collar of the differential cover to the plane face of the outer disk (see also below sketch). Pressure piece 5870 100 069 Load cell 5870 700 004 ц Any deviation from the specified setting dimension must be corrected with a corresponding outer disk. 7609AAX079 A = Setting dimension = 1.05 佳 0.1 mm B = Contact face Τ To obtain a correct measuring result : The housing cover may only be supported on the contact face (B). Ensure that the assembly fixture is only supported on the disk package and not on the disk carrier (5).
7609AAX080 Υ Position housing cover onto pressure piece (see arrow). Insert two hexagon screws into the housing cover to radially fix the disk package. Pressure piece 5870 100 075 7609AAX081 Position the premounted differential with the lifting device onto the housing cover and preliminarily fix with hexagon screws. Lifting device AA00 331 446 7609AAX082 3-223