3-28 3-24-4 HCESPN FMI Description 2315 3 Aux joystick position input voltage above normal or shorted to high source 2315 4 Aux joystick position input voltage below normal or shorted to low source 2315 13 Aux joystick position control block out of calibration 2315 14 Aux joystick position control block parameter invalid 2315 31 Aux joysitck position signal redundancy lost 2304 0 Boom up EPPR valve input value above normal operation range 2304 1 Boom up EPPR valve input value below normal operation range 2304 5 Boom up EPPR valve input current below normal or open circuit 2304 6 Boom up EPPR valve input current above normal or grounded circuit 2304 14 Boom up EPPR valve block parameter invalid 2305 0 Boom down EPPR valve input value above normal operation range 2305 1 Boom down EPPR valve input value below normal operation range 2305 5 Boom down EPPR valve input current below normal or open circuit 2305 6 Boom down EPPR valve input current above normal or grounded circuit 2305 14 Boom down EPPR valve block parameter invalid 2306 0 Bucket in EPPR valve input value above normal operation range 2306 1 Bucket in EPPR valve input value below normal operation range 2306 5 Bucket in EPPR valve input current below normal or open circuit 2306 6 Bucket in EPPR valve input current above normal or grounded circuit 2306 14 Bucket in EPPR valve block parameter invalid 2307 0 Bucket dump EPPR valve input value above normal operation range 2307 1 Bucket dump EPPR valve input value below normal operation range 2307 5 Bucket dump EPPR valve input current below normal or open circuit 2307 6 Bucket dump EPPR valve input current above normal or grounded circuit 2307 14 Bucket dump EPPR valve block parameter invalid 2308 0 Aux.

Up EPPR valve input value above normal operation range 2308 1 Aux. Up EPPR valve input value below normal operation range 2308 5 Aux. Up EPPR valve input current below normal or open circuit 2308 6 Aux. Up EPPR valve input current above normal or grounded circuit 2308 14 Aux. Up EPPR valve block parameter invalid 2309 0 Aux. Down EPPR valve input data above normal operation range 2309 1 Aux. Down EPPR valve input data below normal operation range 2309 5 Aux. Down EPPR valve input current below normal or open circuit 2309 6 Aux. Down EPPR valve input current above normal or grounded circuit 2309 14 Aux.

Down EPPR valve block parameter invalid 2328 0 EHCU sensor power voltage high 2328 1 EHCU sensor power voltage low 2328 3 EHCU sensor power voltage above normal or shorted to high source