Kaiyi — Kaiyi Power Train System Technical Manual

侍# Some fault codes are not applied to this machine. 3-36 Fault code J1939 SPN J1939 FMI Reason Effect (only when fault code is active) 1885 3216 4 Aftertreatment intake NOx sensor circuit - Voltage below normal or shorted to low source. An internal circuit error has been detected by the aftertreatment intake NOx sensor. Possible reduced engine performance. 1887 3226 4 Aftertreatment outlet NOx sensor circuit - Voltage below normal or shorted to low source. An internal circuit error has been detected by the aftertreatment outlet NOx sensor. Possible reduced engine performance. 1896 2791 13 EGR valve controller - Out of calibration.

The EGR valve has failed the automatic calibration procedure at initial key ON. Possible reduced engine performance. 1921 3251 0 Aftertreatment diesel particulate filter differential pressure - Data valid but above normal operating range - Moderately severe level. The soot load of the aftertreatment diesel particulate filter has exceeded the recommended limits. Possible reduced engine performance. 1922 3251 0 Aftertreatment diesel particulate filter differential pressure - Data valid but above normal operating range - Most severe level. The soot load of the aftertreatment diesel par ticulate filter has exceeded the recommended limits. Engine protection derate is enabled.

Possible reduced engine performance. 1938 3597 1 Ecu power output supply voltage 1 - Data valid but below normal operational range - Moderately severe level. Low battery voltage detected by the VGT actuator. Possible reduced engine performance. 1942 101 2 Crankcase pressure - Data erratic, intermittent, or incorrect. The ECM has detected that the crankcase pressure signal is reading an erratic value at initial key ON or during engine operation. None on performance. 1961 2791 0 EGR valve control circuit calculated over temperature - Data valid but above normal operational range - Least severe level. High EGR valve driver temperature has been detected. Possible reduced engine performance.

1962 641 0 VGT Actuator driver over temperature (calculated) - Data valid but above normal operating range - Least severe level. High internal VGT actuator temperature has been detected. None on performance. 1974 101 16 Crankcase pressure - Data valid but above normal operating range - Moderately severe level. The crankcase breather filter requires maintenance. None on performance.