Kaiyi — Kaiyi Power Train System Technical Manual

侍# Some fault codes are not applied to this machine. 3-41 Fault code J1939 SPN J1939 FMI Reason Effect (only when fault code is active) 3165 4363 0 Aftertreatment SCR outlet temperature - Data valid but above normal operational range - Most severe level. The SCR outlet temperature sensor reading has exceeded the maximum engine protection temperature limit. Possible reduced engine performance. 3168 3936 16 Aftertreatment diesel particulate filter system - Data valid but above normal operating range - Moderately severe level. The system has detected a malfunction in the filtering capability of the aftertreatment diesel particulate filter. None on performance.

3186 1623 9 Tachograph output shaft speed - Abnormal update rate. No communication or an invalid data transfer rate has been detected on the J1939 data link between the ECM and the tachograph output shaft speed sensor. None on performance. 3213 1623 19 Tachograph output shaft speed - Received network data in error. The J1939 multiplexing controller has indicated a malfunction of the tachograph output shaft speed sensor. None on performance. 3228 3216 2 Aftertreatment Intake NOx sensor - Data erratic, intermittent, or incorrect. An incorrect NOx sensor reading has been detected by the aftertreatment intake NOx sensor. Possible reduced engine performance.

3232 3216 9 Aftertreatment Intake NOx sensor - Abnormal update rate. No communication or an invalid data transfer rate has been detected on the J1939 data link between the ECM and the aftertreatment intake NOx sensor. Possible reduced engine performance. 3235 4363 16 Aftertreatment SCR outlet temperature - Data valid but above normal operating range - Moderately severe level. The SCR outlet temperature sensor reading has exceeded the maximum temperature limit. Possible reduced engine performance. 3237 4340 3 Aftertreatment diesel exhaust fluid line heater 1 circuit - Voltage above normal or shorted to high source.

High signal voltage detected at the diesel exhaust fluid line heater 1 circuit. Possible reduced engine performance. 3238 4340 4 Aftertreatment diesel exhaust fluid line heater 1 circuit - Voltage below normal, or shorted to low source. Low signal voltage detected at the diesel exhaust fluid line heater 1 circuit. Possible reduced engine performance. 3239 4342 3 Aftertreatment diesel exhaust fluid line heater 2 circuit - Voltage above normal or shorted to high source. High signal voltage detected at the diesel exhaust fluid line heater 2 circuit. Possible reduced engine performance.

3241 4342 4 Aftertreatment diesel exhaust fluid line heater 2 circuit - Voltage below normal, or shorted to low source. Low signal voltage detected at the diesel exhaust fluid line heater 2 circuit. Possible reduced engine performance.