侍# Some fault codes are not applied to this machine. 3-45 Fault code J1939 SPN J1939 FMI Reason Effect (only when fault code is active) 3382 3058 18 Engine exhaust gas recirculation (EGR) system - Data valid but below normal operating range - Moderately severe level. Measured egr flow is lower than commanded. Possible reduced engine performance. 3383 3058 16 Engine exhaust gas recirculation (EGR) system - Data valid but above normal operating range - Moderately severe Level. Measured EGR flow is higher than commanded. Possible reduced engine performance.
3394 4766 18 Aftertreatment 1 diesel oxidation catalyst outlet gas temperature - Data valid but below normal operating range - Moderately severe level. The diesel oxidation catalyst outlet Temperature is below the operating limit Possible frequent need for aftertreatment regeneration. 3396 3750 31 Diesel particulate filter 1 conditions not met for active regeneration - Condition exists. The aftertreatment temperatures are not warm enough for aftertreatment injection. Possible frequent need for aftertreatment regeneration. 3418 191 19 Transmission output shaft speed - Received network data in error.
The J1939 multiplexing controller has indicated a malfunction of the transmission output shaft speed sensor. None on performance. 3422 4344 3 Aftertreatment diesel exhaust fluid line heater 3 circuit - Voltage above normal or shorted to high source. High signal voltage detected at the diesel exhaust fluid line heater 3 circuit. Possible reduced engine performance. 3423 4344 4 Aftertreatment diesel exhaust fluid line heater 3 circuit - Voltage below normal, or shorted to low source. Low signal voltage detected at the diesel exhaust fluid line heater 3 circuit. Possible reduced engine performance.
3425 4344 5 Aftertreatment diesel exhaust fluid line heater 3 circuit - Current below normal or open circuit. Open circuit detected in the diesel exhaust fluid line heater 3. Possible reduced engine performance. 3488 563 9 Anti-lock braking (ABS) controller - Abnormal update rate. No communication or an invalid data transfer rate has been detected on the J1939 data link between the ECM and the anti- lock braking (ABS) controller. None on performance. 3492 251 10 Real time clock - Abnormal rate of change. The real time clock indicates a stuck engine off timer. None on performance. 3494 1081 7 Engine wait to start lamp - Mechanical system not responding or out of adjustment.
Wait to Start lamp has malfunction. None on performance. 3497 1761 17 Aftertreatment diesel exhaust fluid tank level - Data valid but below normal operating range - Least severe level. The aftertreatment diesel exhaust fluid tank level is low. None on performance.