Kaiyi — Kaiyi Power Train System Technical Manual

侍# Some fault codes are not applied to this machine. 3-48 Fault code J1939 SPN J1939 FMI Reason Effect (only when fault code is active) 3575 4334 16 Aftertreatment diesel exhaust fluid pressure sensor - Data valid but above normal operating range - Moderately severe level. The diesel exhaust fluid dosing unit has detected a blockage in the diesel exhaust fluid return flow. Possible reduced engine performance. 3577 4376 3 Aftertreatment diesel exhaust fluid return valve - Voltage above normal or shorted to high source. High signal voltage detected at the aftertreatment diesel exhaust fluid return valve. Possible reduced engine performance.

3578 4376 4 Aftertreatment diesel exhaust fluid return valve - Voltage below normal, or shorted to low source. Low signal voltage detected at the diesel exhaust fluid return valve. Possible reduced engine performance. 3582 4364 18 Aftertreatment SCR catalyst conversion efficiency - Data valid but below normal operating range - Moderately severe level. NOx conversion across the SCR catalyst is too low. Possible reduced engine performance. 3583 5031 10 Aftertreatment outlet NOx sensor heater - Abnormal rate of change. The aftertreatment outlet NOx sensor heater is unable to maintain its normal operating temperature. None on performance.

3596 4334 2 Aftertreatment diesel exhaust fluid pressure sensor - Data erratic, intermittent, or incorrect. The diesel exhaust fluid pressure sensor has reported a reading too high or low for the operating conditions. Possible reduced engine performance. 3649 5024 10 Aftertreatment Intake NOx sensor heater - Abnormal rate of change. The aftertreatment intake NOx sensor heater is unable to maintain its normal operating temperature. None on performance. 3681 3228 2 Aftertreatment outlet NOx sensor power supply - Data erratic, intermittent, or incorrect. The aftertreatment outlet NOx sensor indicates that the power supply to the sensor is incorrect. None on performance.

3682 3218 2 Aftertreatment Intake NOx sensor power supply - Data erratic, entermittent or encorrect. The aftertreatment intake NOx sensor indicates that the power supply to the sensor is incorrect. None on performance. 3697 630 12 Engine control module calibration memory - Bad intelligent device or component. Error internal to the ECM related to engine software failures. Engine may not start or may be difficult to start. 3712 5246 0 Aftertreatment SCR operator inducement - Data valid but above normal operational range - Most severe level. Critical SCR related fault codes have been active for an extended period of time and require immediate attention.

Vehicle speed will be limited to 8 km [5 miles] per hour.