3-83 Problem Cause Remedy Machine will not move Low oil level. Applied park brake. No power to transmission contro- ller. Malfunctioning parking brake solenoid valve. Restricted orifice of PPC valve. Excessive leakage in transmission element. Worn clutch disks. Low or no transmission pressure. Service brake will not release. Failed torque converter. Broken shafts or gears. Broken drive shafts. Broken ring or pinion gear. Add oil. Check parking brake fuse. Check continuity to parking brake switch. Check transmission controller fuse. Remove and inspect parking brake solenoid valve. Check for power to solenoid valve. Remove orifice and check for contamination and/or plugging.
(Do not remove valve housing for this purpose.) Do transmission element leakage test using system pressure. Repair transmission. See transmission pressure is low in this group. Do brake pedal operational check. Do service and park system drag checks. Do torque converter stall test. If engine pulldown in normal, torque converter is good. Drain transmission to determine if large pieces of metal contamination are present. Inspect drive shafts and universal joints for external damage. Repair. If drive shaft rotate with transmission in gear but machine does not move, a differential failure is indicated. Repair.
Machine does not engage in low gear Malfunctioning transmission control solenoid valve. Stuck spool in transmission control valve. Stuck PPC valve. Malfunctioning transmission speed sensor. Check solenoid valve. Remove and inspect transmission control valve spools. Remove end cover to inspect PPC valve. Replace if necessary. Check speed sensor.