Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE 24.2.7 BLEED AIR FROM HEAD END OF ANGLE CIRCUIT l Hydraulic angle-tilt dozer A WARNING When loosening the oil filler cap, oil may spurt out, so turn the cap slowly to release the internal pressure be- fore loosening the cap. Bleed the air if the work equipment has been removed or repaired. 1. Loosen the cap of the hydraulic tank. 2. Start the engine, raise the blade approx. 300 mm from the ground (level with or higher than the frame), then run the engine at low idling. 3. With the engine at low idling, operate between left tilt and right tilt about ten times repeatedly to the end of the cy- linder stroke to fill the tilt circuit with oil. 4.

Operate the blade to the maximum left angle, loosen plug 0 three turns, then loosen valve 0 two turns. 5. Run the engine at low idling and operate the right tilt until no more bubbles come out with the oil from plug @I. After checking that there are no more bubbles in the oil, tighten plug 0. Operate the tilt slowly with the engine running at low idling. 6. Operate the blade to the maximum right angle, and loosen plug 0 three turns. 7. Run the engine at low idling and operate the right tilt until no more bubbles come out with the oil from plug 0. After checking that there are no more bubbles in the oil, tighten plug 0. Operate the tilt slowly with the engine running at low- idling. 3-34