Komatsu — 24.5 EVERY 250 HOURS SERVICE

24. SERVICE PROCEDURE 24.5.4 CHECK LEVEL OF BATTERY ELECTROLYTE Carry out this check before operating the machine. A WARNING l To avoid gas explosions, do not bring fire or sparks near the battery. l Battery electrolyte is dangerous. If it gets in your eyes or on your skin, wash it off with large amounts of water, and consult a doctor. 1. Open the cover behind the operator’s seat. 2. Remove cap 0, and check that the electrolyte is at the specified level (10 to 12 mm above the plate). If the elec- trolyte level is low, add distilled water to the specified level. If the battery electrolyte is spilled, have dilute sul- phuric acid added. 3.

Clean the air hole in the battery cap, then tighten the cap securely. REMARK When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing. 24.5.5 CHECK FAN BELT TENSION, ADJUST Checking The belt should normally deflect by about IO mm when pressed with the finger (with a force of approx. 6 kg) at a point midway between the alternator pulley and fan pulley. Alternator pulley Crankshaft pulley W,X 3-48