DRESSTA Co. Ltd. 560C99/1E — 5.4.7. LUBRICATING FITTINGS

SECTION 5 MAINTENANCE Page 12 LUBRICATION 5.4.7. LUBRICATING FITTINGS WARNING! Never run the engine when cleaning or lubricating the machine because serious injury could result from contacting moving parts. Before servicing the machine, be sure the engine is off, the bucket is lowered, the transmission range gear lever locked in neutral position, the parking brake applied and the electrical master switch is off and the key is removed. The lubricating fittings (see Fig. 5.1.) are to be greased at the intervals indicated in the service chart. Always use a clean lubricator. Wipe all accumulated dirt from fittings before applying fresh grease.

Apply grease at each fitting until fresh grease appears. If grease fails to go through the fitting, determine the cause and correct it. Fig. 5.2. Lubricating Fittings 1 - Transfer Drive 2 - Lower Articulation Pivot 3 - Steering Cylinders 4 - Upper Articulation Pivot L, R- fittings are located on the left (L) hand side and right (R) hand side of the machine frame. Lubricating fittings of other service points are shown in Fig. 5.3. to 5.8. Easier access to service points may be gained by proper positioning of loader linkage. Fig. 5.3. Bucket Cylinder Pivot Fittings OM560C99/1E DRESSTA