SPECIFICATIONS SECTION 6 Page 23 6.13. TORQUE VALUES FOR HYDRAULIC TUBES AND FITTINGS Chart 4 Above torque figures are recommended for plain, cadmium or zinc plated fittings, dry or wet installations. These torques are not recommended for tube with wall thickness of 0.89 mm or less. 6.14. TORQUE VALUES FOR HOSE CLAMPS The following chart 5 provides the tightening torques for hose clamps used in all rubber applications: radiator, air cleaner, operating lever boots, hydraulic system, etc.). Chart 5 DRESSTA OM560C99/1E Size Tubing O.D.
in inches Thread size in inches Torque values for 37° flared fittings, Nm Torque values for O-ring boss plugs, locknuts and 37° flared fittings, Nm 4 1/4 7/16 – 20 12 – 16 8 – 14 5 5/16 1/ 2 – 20 16 – 20 14 – 20 6 3/8 9/16 – 18 29 – 33 20 – 27 8 1/2 3/ 4 – 16 47 – 54 34 – 41 10 5/8 7/8 – 14 72 – 79 47 – 54 12 3/4 1 – 1/16 – 12 104 – 111 81 – 95 14 7/8 1 – 3/16 – 12 122 - 138 95 – 109 16 1 1 – 5/16 – 12 149 – 163 108 – 122 20 1- 1/4 1 – 5/8 – 12 190 – 204 129 – 156 24 1- 1/2 2 – 1/2 – 12 217 – 237 163 – 190 32 2 2 – 1/2 – 12 305 – 325 339 – 407 CLAMP TYPE AND SIZE TORQUE ± 0.6 Nm Radiator, Air Cleaner, Boots, etc, Nm Hydraulic System, Nm "T" Bolt (any diameter) 6.2 ÷7.3 Worm Drive - 1-3/4 in.
Open Diameter & Under 2.2÷ 3.3 4.5 ÷5.6 Worm Drive - Over 1-3/4 in. Open Diameter 4.5 ÷5.6 Worm Drive - Al1 "Ultra-tite" 10.7 ÷11.8 4.5 ÷5.6