OPERATING SECTION 4 Page 23 CAB HEATING AND VENTILATION Fig. 4.13. Side Control Panel 31. Heater Fan Control Switch 32. Heater Temperature Control Knob 33. Air Conditioner Temperature Control Knob 34. Main Switch 35. Window Defroster Fan Switch (If Equipped) 36. Windshield Wiper Switch 37. Rear Window Wiper Switch 38. Windshield Washer Switch 39. Rear Window Washer Switch 40. Air Control Knob 41. Air Intake Mode Control Knob For description of controls refer to Section 4.3 4.6.3. AIR CONDITIONER Fig. 4.14. Block Diagram of A/C Connections The wheel loader may be equipped with an air conditioner to reduce air temperature and relative humidity inside the cab.
An air conditioner consists of the following principal components: 1. Compressor – V-belt driven thru pulley mounted on the LH side of the engine 2. Condenser - radiator mounted 3. Dehumidifier – mounted on a bracket on the RH side of rear frame 4. Evaporator – RH side cab wall mounted 5. Relief valve – integrated with evaporator The a/m components are connected with hoses 6+9, A/C system is filled with R-134A gas. IMPORTANT: If A/C system refilling is required contact Construction Equipment Authorized Distributor. The system must be filled in accordance with the manufacturer’s instructions. DRESSTA OM560C99/1E