SECTION 4 OPERATING Page 36 LOADER OPERATIONS Adjustment of automatic boom kick-out To change the automatic boom kick-out position, raise the boom arms to the desired stopping height (factory set stopping height is maximum boom height). Loosen the bolt holding bar 2 in place and slide it in bracket 3 so as it is positioned directly in front of proximity switch. Tighten the bolt holding the bar. Start the machine and test the adjustment. Repeat this procedure until the automatic kick-out height is obtained. WARNING! Use extra caution when adjusting loader’s bucket leveler or boom kick-out. Use two trained people and guard against accidental movement of the machine or loader linkage.
No personnel is allowed within the reach of loader linkage. Never work or walk under raised bucket without proper blocking. 4.18.3. BUCKET CONTROL LEVER POSITIONS (FIGURE 4.27) Fig. 4.27. Bucket Control Lever Positions E. Rollback B. Hold C. Dump The bucket control lever is situated on the RH side of the operator’s seat and close to the boom control lever (closest to the operator's seat). It has three positions E, B, F ("roll back, "hold", and "dump"). Roll back E To roll the bucket back- load the bucket and pull the lever all the way back. When the automatic leveler is inoperative, the lever automatically returns to the hold position when released.
When the automatic leveler is operative, the lever will be locked automatically with the solenoid latch. This latch can be released manually. Hold B The control lever, if not in E detented position, will return automatically to hold position B when released and will maintain the bucket in the required position. Dump F To dump the bucket, push the lever forward. When the lever is released, it will automatically return to hold position B. OM560C99/1E DRESSTA