DL06 Operation and Maintenance (T) = 0.015 x S (about 1.5mm per 100mm). T = 0.015 x *S (mm) (T : Deflection, S : Span) (D − d)2 * S = C2 − (mm) 2 C : Distance of pulleys (mm) D : Large pulley diameter (mm) d : Small pulley diameter (mm) (4) Measuring tension ① Lower indicator arm (1) into the scale z Apply tester to belt at a point midway between two pulleys so that edge of contact surface (2) is flush with the V- belt. z Slowly depress pad (3) until the spring can be heard to disengage. This will cause the indicator to move upwards. z If pressure is maintained after the spring has disengaged a false reading will be obtained.
191 Maintenance of Major Components Maintenance of Major Components Printed in Nov. 2006 PS-MMA0418-E1A