DL06 Operation and Maintenance 2) Distortion of lower surface z As shown in figure, measure the cylinder head's distortion at (t) 6 directions with horizontal ruler and clearance gauge. A B C D z If the measured value is beyond the limit value, correct E F it by means of the fine grinding paper or grinding machine. z If it is beyond the max. allowable value, replace the cylinder head. 3) Flatness z Check the flatness of the installing surface of cylinder head's intake and exhaust manifolds with horizontal ruler and clearance gauge. 4) The hydraulic test z The hydraulic test of cylinder head is same as the cylinder block test. 73 Measurement and Inspection of Major Parts Printed in Nov.
2006 PS-MMA0418-E1A Standard Limit Warpage 0.08 mm or less 0.15 mm Thickness : t (reference) 104.9 ~105.1mm 1 04.4mm Standard Limit 0.15 mm 0.3 mm