PACCAR 567 — Engine Fan

MAINTENANCE - Engine Maintenance 2. Slip the belt around the idler pulley attached to the automatic tensioner. 3. Release the automatic tensioner. 4. Check the belt alignment on each pulley. The belt must fall between the flanges of each pulley. conditions (e.g. fan belt misaligned or excessive wear/damage, etc.). With the engine idling and the hood open, stand at the front of the vehicle. Listen for any noises coming from the fan hub. Bearings that have lost lubricant and are dry will typically emit a squeal or a growl when the engine is at operating temperature and the fan clutch is engaged. If noise is detected, have the fan bearings inspected by an authorized dealership.

Engine Fan WARNING 5 DO NOT work on or near the fan with the engine running. Anyone near the engine fan when it turns on could be injured. If it is set at MANUAL, the fan will turn on any time the ignition key switch is turned to the ON position. In AUTO, it could engage suddenly with- out warning. Before turning on the igni- tion or switching from AUTO to MAN- UAL, be sure no workers are near the fan. Failure to comply may result in death or personal injury. Engine Fan Blade Verify that there is enough fan blade clearance with the fan shroud. The recommended distance around the fan shroud is 1 in. (25 mm) from front edge of any fan blade-to-radiator side member. Minimum clearance is 3/4 in.

(19 mm). Rear edge of any blade must be no closer than 3/8 in. (9 mm) to the nearest engine component. If this cannot be obtained, the fan spacer or fan is incorrectly placed. The leading edge of any fan blade must be 1 in. (25 mm) from the inside edge of the shroud. Follow these guidelines to check your engine fan: With the engine shut off, check the fan hub bearings for looseness, loss of lubricant, and any abnormal Y53-6126-1A1 (01/21) 267