Komatsu — Full page photo print Komatsu

. OPERATION MACHINE OPERATIONS AND CONTROLS Check for Water and Sediment in Water Separator, Drain Water drain water under drain hose (3). 3. Loosen drain valve (4) and drain the water. 4. When fuel starts to drain from drain hose (3), tighten drain valve (4) immediately. monitor, it indicates that water is accumulated in transparent cap (2). In this case also, use the procedure above to drain the water. REMARK If transparent cap (2) is dirty or it is difficult to see the inside, clean transparent cap (2) when replacing fuel pre-filter cartridge (1). When the drain valve (4) has been removed during the cleaning operation, coat the O-ring with grease and tighten until it contacts the bottom.

3 - 113 n the right side of the machin rator forms one unit with fuel pre-filter ( dge the water level and amou nt of sediment transparent cap (2). If there d at the bottom, set a contain is any wat er to catch er or the On this machine, a sensor is installed to detect if water is arent cap (2). ator monitor (5) lights up red on the machine accumulated in transp When the water separ REMARK When only the water s eparator monitor lights up, it lights up in the position shown in the diagram on the right. If other monitors also light up the same time, the w ater separator monitor lights up at a different position.

NOTICE ted in transparent cap (2) freezes, the water separator monitor may not light up. After the engine is If the water accumula r separator m started, as the temper suddenly light up. In ature around fuel pre-filter (1) inc reases, the froze n water will melt and the water separator monitor may cold areas, even if the water sep arator monit or does n ot li ght up, drain the wate r frequently. If the water inside tran sparent cap (2) freezes, check tha t the frozen water has melted completely, then u se the procedure above to drain the water.