. MAINTENANCE MAINTENANCE PROCEDURE CHANGE OIL IN FINAL DRIVE CASE WARNING 4 - 69 EVERY 2000 HOURS MAINTENANCE Carry out the periodi c maintenance work o f every 100, 2 50, 500 a nd 100 0 hours of operati on at the same tim The parts and oil are at high temperature immediately after th e engine is stopp ed, an d may cause s erious burns. Wait f or the temperature to go do wn before starting the operation If there is still pressu re remaining inside the case, the oil or p lug may fl y out. L oosen the plug slowl y to release the pres sure. Please do not stand in front of the plug whe n you loosen the Oil replacement a mount: 3.3l (0.87 US gal) (both left and right) Prepare a handle. 1.
Set the TOP mar k at the top, with the TOP mark and plug (P) perpendicular to the ground surface. 2. Set a container u nder plug (P) to catc h the oil. 3. Remove plugs (P ) and (F) with the handle and drain REMARK Check the O-rings in the plugs for damag e. If necessary with new ones. 4. Tighten plug (P). he hole of plug (F). 5. Add oil through t 6. When oil begins t o overflow from the p lug ( F) h ole, in stall plug (F). Tightening torqu 68.6 ± 9.8 Nm (7 e of plugs (P) and (F): ± 1 kgm, 50.6 ± 7.2 lbft) e of plugs (P) and (F): ± 1 kgm, 50.6 ± 7.2 l REMARK There are two plugs ( F). Add oil through the one easier to f ill oil and through which no int ernal gears are to be seen .