MAINTENANCE 24.2.9 CLEAN THE AIR CONDITIONER CONDENSER WARNING Do not wash the condenser with a steam cleaner, which can develop enough heat to break down the condenser. Remove mud or dust from the air conditioner condenser with water. Use care when washing with high pressure equipment -- apply the water from a reasonable distance. Excessively high water pressure could deform the fins. 24.2.10 OPERATE THE AIR CONDITIONER OFF SEASON Operate the system for three to five minutes once a month during the off-season, regardless of the weather. Allow the engine to run at low speed idle. This brief operation circulates lubricant through the compressor, which it needs for long life.
24.2.11 CHECK WINDOW WASHING FLUID, ADD FLUID Check the fluid level in window washer tank (1). When the fluid is low, add automotive window washing fluid. To prevent the nozzle from clogging, be careful to keep the fluid free of dust. 24.2.12 LUBRICATE WORK EQUIPMENT CONTROL VALVE LINKAGE (2 PLACES) If the work equipment control lever is stiff or does not move smoothly, apply grease. 1. Using a grease gun, pump in grease through the grease fittings shown by the arrows. 2. After greasing, wipe away any old grease that was pushed out. 3-38 WA420-3MC