Komatsu — 12.2 STARTING ENGINE

12. OPERATION 8. When the engine is started, release the key of starting switch 2 and the key will return automatically to ON. If the engine does not start through the steps specified above, turn key of starting switch 2 to OFF position and repeat Steps 2 to 8 at an interval of approx. 2 minutes. 9. After the engine is started, when the engine is running smoothly, and the exhaust gas color becomes normal, turn OFF pre-heating switch 4 . REMARK After the engine is started, when the water temperature reaches about 20°C, pre-heating monitor 5 flashes to signal that after- heating is finished and after-heating is canceled automatically.

If pre-heating switch 4 is not turned OFF, however, pre-heating monitor 5 does not go off. Accordingly, turn off pre-heating switch 4 to put out pre-heating monitor 5 after the following elapsed time. The time which should elapse before turning pre-heating switch 4 off varies with the ambient temperature. Check the time with the following table. Do not raise the engine speed higher than the middle level during the time from the start of the engine until turn-off of pre- heating switch shown in the above table. 2-71 Ambient temperature Time from the start of engine until turn-off of preheater switch 15 – 0°C 1 – 2 minutes Below 0°C 3 – 5 minutes