16. TROUBLESHOOTING 16.4 OTHER TROUBLE 16.4.1 ELECTRICAL SYSTEM ( ): Always contact your Komatsu distributor when dealing with these items. In cases of abnormalities or causes which are not listed below, please contact your Komatsu distributor for repairs.
2-113 Main causes ‡ Defective wiring ‡ Defective adjustment of alternator Lamp flickers while engine is running belt tension For details, see EVERY 250 HOURS SERVICE Even when the engine is rotating, the charge caution pilot lamp does not go out ‡ Defective alternator ‡ Defective wiring (‡ Replace) (‡ Check, repair) Abnormal noise is generated from alternator ‡ Defective alternator (‡ Replace) Starting motor does not turn when starting switch is turned to ON ‡ Defective wiring ‡ Insufficient battery charge ‡ Defective starting motor (‡ Check, repair) ‡ Charge (‡ Replace) Pinion of starting motor keeps going in and out ‡ Insufficient battery charge ‡ Charge Starting motor turns engine sluggishly ‡ Insufficient battery charge ‡ Defective starting motor ‡ Charge (‡ Replace) Starting motor disengages before engine starts ‡ Defective wiring ‡ Insufficient battery charge (‡ Check, repair) ‡ Charge Preheating pilot lamp does not light up ‡ Defective wiring ‡ Defective controller ‡ Defective monitor (‡ Check, repair) (‡ Replace) (‡ Replace) Even when engine is stopped, charge caution pilot lamp does not light up (starting switch at ON position) ‡ Defective wiring ‡ Defective monitor (‡ Check, repair) (‡ Replace) Outside of glow plug is not warm when touched by hand ‡ Defective wiring ‡ Disconnection in glow plug ‡ Defective operation of heater relay switch (‡ Check, repair) (‡ Replace) (‡ Replace)