24. SERVICE PROCEDURE 8. Remove mounting bolts 5 of the 2 filter covers 4 at the top of the tank, then remove the covers. When doing this, the cover may fly off because of the force of spring 6 , so keep the cover pushed down while removing the bolts. 9. Remove spring 6 and bypass valve 7 , then remove element 8 . 10. Check that there is no foreign matter inside the tank before cleaning it. 11. Install a new element, then install bypass valve 7 , spring 6 , and cover 4 . If the O-ring of the cover is damaged or deteriorated, replace it with a new part. 12. When installing the cover bolts, push down the cover and tighten the bolts evenly. 13.
Add engine oil through oil filler port F to the specified level, then install cap F and air bleed plug 1 on filter case. For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”. 14. Check that the hydraulic oil is at the standard level. For details, see “24.5 EVERY 100 HOUR SERVICE”. 15. Loosen plug 9 on top of the tube at the suction side of the piston pump. There is one plug for each pump, so loosen all plugs (2 places). 16. Loosen the connector at block A side of case drain hose 0 of the piston pump.
The case drain hoses (x 3) for each pump are connected to block A , but loosen only the connector of case drain hose 0 con- nected to the top of the block. There is no need to loosen the connectors of the other two case drain hoses. 17. Continue until oil flows out from plug 9 (2 places) and the connector of hose 0 . After the air has been completely bled, tighten plug 9 (3 places) and the connector of the hose. 3-75