Komatsu — 30.1 MAIN MONITOR FAILURE DISPLAY

30. MAIN MONITOR FAILURE DISPLAY If an error code is displayed on the main monitor portion (normally the speedometer display) of the machine monitor, follow the corresponding table when carrying out the selfdiagnostic troubleshooting below.

30.1 MAIN MONITOR FAILURE DISPLAY (Contents of operator’s actions against each error code) 5-16 Error code Transion control system Option Alarm buzzer Action by operator Joystick control system Problem system Condition of machine Problem system Condition of machine E00 Disconnection in travel speed sensor system Does not shift gear auto- matically (switches to manual gear shifting) Disconnection, short circuit, or short circuit with ground in joystick FNR signal system (or L, R signal system) Returns to neutral (Steering with steering wheel can be selected.) No Normal work possible with manual operation Disconnection in engine speed sensor system Engine speed taken as 2100 rpm (there is gear shifting shock.

Gear does not shift in auto-shift mode, however.) – – Normal work is possible in manual mode. (If joystick is installed, normal work is possible with steering wheel in manu- al shift mode.

CALL Disconnection, short circuit with ground, or short circuit in shift lever system Becomes neutral, travel impossible (judges controller input as N) – – Yes Stop machine, turn starting switch OFF, do same as above, then call service Disconnection, short circuit with ground, or short circuit in F, R solenoid signal system Becomes neutral, travel impos- sible (solenoid signal output OFF) – – Disconnection, short circuit with ground, or short circuit with speed range solenoid signal system Becomes neutral, travel impos- sible (solenoid signal output OFF) –– –