Komatsu — 31. HANDLING AUTO-GREASING SYSTEM

31. HANDLING AUTO-GREASING SYSTEM 1. Check that a pail or grease is in the grease pump case. If there is not sufficient grease in it, supply new grease. 2. Check that grease does not leak from the piping between the pail or grease pump case 1 and follower plate 2 . NOTICE If follower plate 2 is not used, pump 3 cannot suck up the grease even if there is sufficient grease in the pail. Accordingly, do not remove follower plate 2 . The pails of the following sizes are available. Use follower plate 2 of the proper size for each size of the pail. For applicable combinations of pails, follower plates 2 and level gauges 4 , see the above table. 3.

Turn the starting switch ON and check that lamp 5 on the monitor panel lights up. Lighting: Normal When the auto-greasing system is turned on and it has no abnormalities, or when the grease pump op- erates to supply grease and the grease supply line pressure reaches the specified level, the indicator lamp lights up. Flashing: When any wire in the electric circuit is broken or when the supply line pressure drops below the specified level while the grease pump is operating, the indicator lamp flashes. The lamp flashes after the pump starts operation until the supply line pressure reaches the specified level, but it lights up when the pressure reaches the speci- fied level.

This does not indicate trouble. If the lamp does not stop flashing (does not light up), there is trouble with the machine. In such cases, stop the machine immediately and consult your Komatsu distributor. 5-19 Part No. of follower plate Applicable pail Level gauge 427-S95-2510 Inside diameter of pail ø275 – ø290 mm 427-S95-2570 427-S95-2520 When pail is not used