Section C - Electrics Basic System Operation Refuelling Pump Refuelling Pump Operation Refuel Pump Relay +24V EMS ECU1 M O/P5 (C-13) CAN bus Refuel Pump Motor Fuel Level Sensor Ov Ref (A-20) I/P4 (A-8) I/P16 (A-35) Refuel Pump Switch C030500GB-3 Fig 96. ECU1 Requirements If a second falling edge is detected on the fuel pump input, then the feature is de-activated and the fuel pump output is turned off. A refuelling pump can also be installed on the machine. This pump can be used in two different modes: automatic or manual. Note: If any errors are present on the fuel level sensor, then the refuel pump's automatic mode is not allowed. Note:
The refuel pump feature is only present when the machine is fitted with a new harness. If the machine is not fitted with a new harness the input and output pins used for this feature are assigned to other functions Automatic Mode A short press of the fuel pump momentary switch is used to turn on and off the fuel pump's automatic mode. When the refuelling pump switch is pressed, a high (+Vbatt) is measured at the input to the ECU1. When the button is released, the input is open circuit and a `low' will be measured by the ECU1. If the button is held for less than 2 seconds, then this falling edge will trigger the refuelling pump feature into automatic mode.
While in automatic mode, the output to the refuelling pump relay is energized. The fuel level input is monitored during this functionality. When the fuel level reaches the Max Refuel Level, the fuel pump output is turned off. The filtering that is normally used to smooth out fuel level readings is not used in this case so that there is no delay in the fuel level reading. C-106 C-106 9803/9880-3