JCB — 80.pdf (p.80)

Section E - Hydraulics Hydraulic Pump/Regulator Hydraulic Pump Operation Hydraulic Pump Regulation The regulator on pump A1 works the same as above. For this description pump A2 has been used. For schematic, K Fig 1. ( T E-17) If Q max cut is selected a 40 bar servo pressure signal from the 8 spool solenoid block enters the pump at port Pm2. This will partly select the Q max cut piston J . which pushed the piston against spring A and reduces the pump to 60% maximum flow. On start up, the swash plate piston F is held in the maximum flow position by the spring A .

Once oil as passed through the valve block a 37 bar (537 Ib in 2 ) negative control signal enters port Pi2 and is available to the negative control piston D . This acts against spring A to move the spool across allowing pump pressure to cross the spool and pressurise the large diameter side of the swash plate piston F . Pressure is now available to both sides of the swash piston F , but due to the difference in surface areas the piston moves to the minimum flow position. When a service is selected the negative control pressure drops. Piston D now moves back due to the spring pressure.

This allows the oil in the larger area side of the swash plate piston F to vent to tank, but pump pressure oil is still available to the smaller diameter side so the pump moves over to the maximum flow position. As the pump pressure increases, the pressure seen at the small diameter end of the swash plate piston F is also seen at the piston C . At the same time any pressure generated at pump A1 is also seen at pump A2 at the piston C . As the pressure increases at piston C via line B it starts to push against spring A . When the pressure has increased to approximately 200 bar (2900Ib in 2 ) the spool will start to select.

This will now allow pump pressure to the large diameter side of the swash plate piston F which will proportionally start to select minimum flow. When L mode is selected a 40 bar (580 Ib in 2 ) signal from the Max flow cut solenoid on the 8 spool solenoid is sent to Pm2 of the pump. This prevents the pump from selecting 100% flow and limits it to 60% flow. In A mode the secondary pressure drops to approximately 10 bar (145Ib in 2 ). This reduction in secondary pressure at piston D has to be made up for by higher pump pressure at pistons C and E before the Sumater spool starts to select, hence more hydraulic horsepower. E-75 E-75 9803/9880-3