Section E - Hydraulics Service Procedures Pressure Testing - General Pressure Testing - General Confirmation of the Oil Temperature Confirm the oil temperature is between 45°C - 55°C using the self check function. If the temperature is low use the following warm-up procedure. Warming-up Procedure 1 Turn the throttle control to mid-range and make sure the work mode is set to E. 2 Run the engine until the coolant temperature gauge reads within the normal (green) range. 3 Set the servo isolator switch to ON to enable the hydraulic servo controls to be operated. 4 Operate the bucket control slowly until it reaches one end of its travel and leave it there for 10 seconds.
5 Operate the bucket control slowly to the other end of its travel and leave it there for 10 seconds. 6 Repeat steps 4 and 5 for 10 minutes to warm up the hydraulic circuit. 7 Operate the excavating controls three to five times in each direction to distribute warm hydraulic oil around the system. Note: All pressure testing to be carried out with the engine set at minimum engine revs unless otherwise stated. E-216 E-216 9803/9880-3