Section E - Hydraulics Service Procedures Slew Motor Pressure Relief Slew Motor Pressure Relief 1 Prepare the machine TE-015 Note: If the water-proof slew lock solenoid valve is not removed. Full slew pressure can not be read. a Operate the dipper out and lower the boom to set the bucket on the ground. Note: Pressure measurement is also possible on the slew motor, upper section. 5 If the readings are outside the limits, continue as below. 6 Pressure Adjustment a Make the machine safe, refer to Section E, Service Procedures. C030150-1 Fig 7. b Make the machine safe, refer to Section E, Service Procedures. b Remove relief valve to be adjusted.
c The difference between the set pressure and the present pressure determines the number of shims E required for adjustment. 2 Connect a 0-400 bar (0 - 6000 lb/in 2 ) pressure gauge and adaptor to test point TP2 . 3 Initiate slew lock procedures. 7 Remove the relief valve assembly from the slew motor. a Remove the water-proof connector on the slew lock solenoid valve. Note: If both relief valves are removed at the same time, mark them left and right to facilitate re-assembly in the correct position. b Press the slew lock switch which is on the right hand console inside the cab, and confirm that the slew lock symbol appears on the monitor.
8 Disassembly a Place the relief valve in a vice and remove the cap A with a 14 mm hexagonal socket, take out the piston C , liner B poppet E , spacer D , shims E and spring F . graphicA335121I c Start the engine, (error codes may appear for disconnected solenoid) and operate the engine at around 1000 rpm, then operate the slew lever slowly. Listen to confirm that the relief sound is heard and that the machine does not slew. E C d Run the engine at minimum no-load speed and in the E mode. F D e Operate the slew lever. B A 4 The pressure gauge reading should be compared to the technical data at the start of this section. If it is outside the limits adjust the slew motor relief valve as below.
A405850-C1 Fig 8. b Add shim to increase pressure. Remove shim to decrease pressure. E-224 E-224 9803/9880-3