Section E - Hydraulics Fault Finding Main Control Valve Main Control Valve Table 1. E-235 E-235 9803/9880-3 Symptoms Possible Causes Countermeasures Spool sticking 1. Oil temperature is abnormally high. Remove the obstruction. 2. Hydraulic oil is dirty Replace the hydraulic oil and clean the circuit at the same time. 3. Port connector is tightened too much Check the torque. 4. Valve housing is deformed due to Installation Loosen the installation bolt and check. 5. Pressure is too high Attach pressure gauge to pump port and ram port and check the pressure. 6. Spool is bent Replace the valve assembly. 7. Return spring is damaged Replace the damaged parts. 8.
Spring or cap is not on straight Loosen the cap and after aligning, tighten. 9. Temperature inside valve is not even. Warm up the circuit. Spool does not stroke 1. Valve is clogged inside with dirt Remove the dirt (flushing). Load cannot be maintained 1. Oil leakage from the ram Check the ram. 2. Oil is by-passing from the valve spool Replace the valve assembly. 3. Oil leakage from the port relief valve Remove the port relief from the housing and clean the housing seat and relief valve seat. 4. Oil leakage from the lock valve Disassemble the lock valve and clean the poppet seat and sleeve, plug seat. If the seat is damaged, replace the poppet, or lap the poppet and seat.
When the spool is selected from neutral to raise position, the load falls. 1. Foreign matter in load check valve Disassemble the check valve and clean. 2. Check valve poppet or seat damaged Replace the poppet or lap the poppet and seat part.