Section C - Electrics Basic System Operation Engine Throttle Control Engine Throttle Control Operation Fig 19. The maximum rev/min value for each mode is specified in software. The maximum rev/min value is used as A mode maximum. E mode maximum is 100 rev/min less than A mode maximum. P & L mode maximum is 200 rev/min less than A mode maximum K Fig 20. ( T C-19) . During calibration the ECU noted the maximum and mini - mum positions of the throttle position sensor.
The maximum point became A mode maximum When the working mode is selected the ECU will scale the full deflection of the throttle dial (0~5v) to adjust the engine speed between the idle position and the maximum speed for the particular mode selected. C-18 C-18 9803/9880-3