honda — Control Boxes and Templates

10. CONTROL BOXES AND TEMPLATES SCREW(2) a 6. Before installing the 8 x 35 mm control lever bolt, install the control cables into the control box (see page 10-23). POWER TRlMFlLT CONTROL SWITCH WIRE \ LEVER \ \ I 9. Install cover C and tighten the screws securely. TORQUE: 2 N.m (0.2 kg-m, 1.4 ft-lb) I NOTICE I HOLD-DOWN Overtightening the mounting screws can damage or distort the control box. SWITCH WIRE CONNECTOR (3) Route the power trimhilt switch wire harness as shown. Install the hold-down plate and tighten the two screws. Connect the switch wire connectors. CONTROL LEVER BOLT, 8 x 35 mm \ / (apply threadlock) WASHER 8.

With the control lever in the neutral position, apply one or two drops of Hondalock 1 (P/N 0871 3-0001) or commercially available Loctite 271@ to the threads. Install and tighten the 8 mm bolt. TORQUE: 20 N.m (2.0 kg-m, 14 ft-lb) 10-22 Date of issue: June 2003 0 2001-2003 American Honda Motor Co., inc.