. MAINTENANCE SERVICE PROCEDURE CHECKING FUNCTION OF ACCUMULATOR NOTICE 4 - 86 Replace the accumulat or ever y 2 y ears or every 4000 hours, whichever Check the n itrogen gas charge pressure a 1. Stop th e machine o n firm, level ground 2. Operate the parking brake leve r to LO CK position (L). 3. Raise th e work equ ipment (blade) to t he maximum height Carr y out the following pro cedure for lo wering the blade to t he ground within 15 seconds after stop ping the engine. Whe n the eng ine is stoppe d, the pressu re inside the accumulator gradually goes down, so this inspe ction can be carried ou t only immediately after the engi ne is stopped 4.
While h olding the w ork equipment at th e highest p osition, t he eng ine starting switch key t o OFF position (A). 5. Turn th e engine sta rting switch key to ON position (B)