Komatsu — CAPACITOR CHARGE LIGHTS

OM2049 2/13 Safety - Section 20 Page 20-17 Observe both capacitor charge lights (CCL1, CCL2). CCL1 is on the outside of the contactor box. CCL2 is on the switch panel inside the low voltage area. The lights will stay illuminated as long as the voltage on the DC link is greater than 50 VDC. Refer to Figure 20-8. CAPACITOR CHARGE LIGHTS Verify functionality of the measurement equip- ment using site-approved procedures both before and after performing control group mea- surements. Failure to observe these precautions may result in death or serious personal injury. Hazardous voltages may be present in this equip- ment even if the engine and capacitor charge lights are off.

Use measurement and protective equipment rated for 2000 VDC minimum to verify that no voltage is present before touching any terminal. FIGURE 20-8. CAPACITOR CHARGE LIGHTS 1. Exterior Capacitor Charge Light (CCL2) 2. Interior Capacitor Charge Light (CCL1) 3. Information Display Panel 4. DC Link Capacitors