OPERATION DIAGNOSTIC FUNCTION — MACHINE INOPERATIVE The machine shuts down when the system detects any of the following problems: High oil temperature Transmission oil pressure low System voltage less than 7V Electronic card defect During the self-test and when any of the above conditions are detected, the system: flashes the red warning LED (14), sounds 3 beeps (each beep 1 second), displays a message (15), turns off all solenoid valves. Contact your local Komatsu distributor to diagnose the system and to make the needed repairs. DIAGNOSTIC FUNCTION — MACHINE OPERABLE If a fault is detected and it is not serious, the machine continues to run, but the: red warning LED (14) flashes.
system sounds three beeps, each beep 1 second. fault code flashes on the display (15) instead of the selected gear. If a clutch-filling pressure sensor becomes defective, the system cannot engage the gear that corresponds to the defective sen- sor. If the 2nd and 3rd gear pressure sensors become defective, the system maintains the default semiautomatic logic; auto- matic logic cannot be selected. If the 2nd gear solenoid becomes defective, the system automatically selects 1st gear instead. If the RPM sensor becomes defective, automatic logic (AU) cannot be selected. Contact your local Komatsu distributor to diagnose the system and to make the needed repairs. 2-22 WB140PS-2N WB150PS-2N