MAINTENANCE BASIC TROUBLESHOOTING If the problem or failure is not listed in the troubleshooting section, contact your Komatsu Dealer immediately and have them check the problem. THE BATTERY When checking or handling the batteries, stop the engine and turn the ignition switch to the OFF position before making repairs. Before starting the engine, use a damp cloth to wipe off the dust accumulated on the top surface of the battery. Because the battery generates hydrogen gas, a possibility of explosion exists. Do not bring lighted cigarettes near the battery or do anything that will cause sparks. Battery elec- trolyte is dilute sulfuric acid and it will attack your clothes and skin.
If battery acid gets on your clothes or on your skin, immediately wash off the battery acid with large quantities of water. If battery acid gets in your eyes, flush your eyes with large quantities of fresh water and consult a doctor immediately. When handling batteries, always wear protective goggles and rubber gloves. SERVICING THE BATTERY If battery tops are dirty, clean with diluted baking soda and warm water solution. Before charging or servicing the battery, disconnect the cable from the negative terminal of the battery. The unusually high voltage will damage the alternator.
While charging the battery to avoid gas explosions, cover the battery caps with rags soaked in a baking soda solution. If electrolyte temperatures exceeds 45° C (113° F), stop charg- ing the battery. Turn off the charger as soon as the battery is charged. Overcharging the battery may cause overheating, decreasing the quan- tity of electrolyte, buckling the plates, or both. Add distilled non-min- eral based water when the battery is low. Do not over fill the battery. Always wear protective clothing when servicing the battery. REMOVAL AND INSTALLATION When removing the battery, first disconnect the cable from the negative terminal.
If a tool touches a cable connecting the pos- itive terminal and the chassis, there is a danger of sparks. When installing the battery, the ground cable should be connected to the ground terminal as the last step. the illustration below shows the proper removal and installation order. WB140PS-2N WB150PS-2N 3-5