Komatsu — NOTES REGARDING LUBRICATION

MAINTENANCE NOTES REGARDING THE ELECTRICAL SYSTEM If the cables are wet or their insulating material is damaged, the electrical system may short, and may result in machine malfunctions. The maintenance operations required for the electrical system are the following: 1. Check the alternator belt tension. 2. Check the alternator belt for damage or breakage. 3. Check the battery electrolyte level. Do not remove or eliminate any electrical component installed on the machine and do not install any electrical component with characteristics different from those specified and approved by Komatsu. Be careful to keep the electrical system dry.

When working on seashores or river or lake banks, protect the jack plugs from corrosion. Do not connect any optional electrical device to the fuses, ignition switch, battery, relays, etc. For the installation of any optional equipment, contact your Komatsu Dealer. If any electric welding needs to be done, disconnect the battery and the alternator before welding. NOTES REGARDING LUBRICATION Perform lubrication with specified grease or oil, according to the ambient temperature. The maintenance operations required for the components that need lubricating are the following: Check the fluid and lubricant levels. Change the oil at the recommended intervals.

Inject grease through the grease fittings. Always clean the grease fittings before injecting grease and remove any excess grease after lubrication. Keep the lubricants at the correct levels; avoid excessive or insufficient quantities. WB140PS-2N WB150PS-2N 3-11