Komatsu — CHECK BATTERY ELECTROLYTE LEVEL

MAINTENANCE CLEAN THE OUTSIDE OF RADIATOR Do not direct compressed air, steam, or water at a person or injuries may result. Always wear safety goggles. Clean the outside of the radiator with compressed air, low-pressure water, or steam. Cleaning products are available on the market and can be used. Follow the instructions on the package. Wash the parts and then thoroughly dry them. # Do not use cleaning products that contain even a small quantity of oily substances because they attract dirt. Dirt on the radiator interfere with the heat exchange process, which could cause an overheating condition.

# Clean the outside of the radiator whenever the radiator is dirty with oil, diesel oil, greasy or oily substances. CHECK BATTERY ELECTROLYTE LEVEL Check the battery level with the machine on flat ground and after stopping the engine. If the battery level is low, add dis- tilled water. Always wear safety goggles and waterproof gloves when servicing the battery. To prevent gas explo- sions, do not have flames near the battery or do not smoke while servicing the battery. Avoid producing sparks from short circuits that would cause the battery to explode. If electrolyte gets in your eyes, pour plenty of water in your eyes and consult a doctor immediately.

If electrolyte gets on your skin, immediately wash the skin with soap and water. The battery (1) can be reached after removing the cover (2) fastening screws (3). Use a 17 mm hexagon wrench. The electrolyte level in each cell must be about 6 mm (0.24 in.) above the plate edge; if necessary, add distilled water only. To reach the filling holes of the cells, first remove guard (4). After fin- ishing, reinstall the guard (4) and cover (2) with fastening screws (3). # Add distilled water before starting work so the water can mix with the electrolyte and prevent the water from freezing. # Before reinstalling the cell plugs, make sure that the breather holes are not clogged.

# Make sure that the connection terminals are not oxidized. If neces- sary, clean them and cover them with antioxidation grease. WB140PS-2N WB150PS-2N 3-43