Komatsu — CHANGE THE HYDRAULIC OIL AND CLEAN THE SUCTION FILTER

MAINTENANCE CHECKING AND ADJUSTING ENGINE VALVE CLEARANCE # The check and adjustment of the engine valve clearance requires use of special tools. Thus, have this check performed by your Komatsu Dealer. MAINTENANCE EVERY 2,000 HOURS Perform these operations together with those to be initiated every 50, 250, 500, and 1,000 HOURS. After stopping the engine: Position the machine so that maintenance can be performed. Operate the controls more than once to release the residual pressures from the hydraulic lines. Slowly loosen the filler cap. Allow time for the oil to cool down until it is from 40° to 45° C (104° to 113° F) before performing any maintenance. Immedi- ately clean up any spilled oil.

Oils, filters, coolant, and the battery are considered special waste and must be collected and disposed of according to all antipollution regulations. CHANGE THE HYDRAULIC OIL AND CLEAN THE SUCTION FILTER # On machines using HEES, change the oil after the first 500 hours of operation and every 2,000 hours thereafter. Or, at least once a year. Using a 17 mm hexagon wrench, remove the screws (2). And then remove the upper platform (1) to access the filter. WB140PS-2N WB150PS-2N 3-57