Kaiyi — Kaiyi Power Train System Technical Manual

(4) Output flange on converter side Output flange on converter side 刮 Use driver (S) to mount shaft seal, with the sealing lip showing to the oil sump. S Driver 5870 048 057 侍 Use of the specified driver (S) ensures the exact installation position. Fill space between sealing lip and dust lip with grease. Wet outer diameter (rubber-coated) with spirit. 侍 HL940TM379 Mount output flange (1) until contact is obtained. 刯 1 HL940TM380 到 Insert O-ring 38 佴 4 into the space between output flange and shaft. Fix output flange (1) by means of washer (2) and hexagon screws (3). Oil hexagon screws before the assembly. 3 1 2 余 Tightening torque (M8/10.9 佴 25) :

3.47 kgf 余 m ( 25.1 lbf 余 ft) 侍 It is always necessary to use new hexagon screws. HL940TM381 3-185