Kaiyi — Kaiyi Power Train System Technical Manual

4. FAULT CODE FAULT CODE G : General C : Cummins Engine application equipment S : Scania Engine application equipment 3-19 1) MACHINE FAULT CODE DTC Diagnostic Criteria Application HCESPN FMI G C S 101 3 10 seconds continuous, Hydraulic Oil Temp. Measurement Voltage > 3.95 V 侑 4 10 seconds continuous, Hydraulic Oil Temp. Measurement Voltage 侑 (Results / Symptoms) 1. Monitor – Hydraulic Oil temperature display failure 2. Control Function – No warming up operation, No fuel warmer function operation, High hydraulic oil temperature warning failure (Checking list) 1. CN-58B (#23) – CD-01 (#2) Checking Open/Short 2.

CN-58B (#25) – CD-01 (#1) Checking Open/Short 202 0 10 seconds continuous, Steering main pump pressure Measurement Voltage > 5.3 V 侑 4 10 seconds continuous, Steering main pump pressure Measurement Voltage 侑 (Results / Symptoms) 1. Monitor – Steering main pump press. Display failure 2. Control Function – No automatic Emergency steering operation, ECO gauge display failure 3. RMS – Working hours accumulation failure (Checking list) 1. CN-58B (#35) – CD-39 (B) Checking Open/Short 2. CN-58A (#11) – CD-39 (A) Checking Open/Short 3.

CN-58B (#25) – CD-39 (C) Checking Open/Short 204 0 10 seconds continuous, Boom cylinder ‘head’ pressure Measurement Voltage > 5.3 V 侑 4 10 seconds continuous, Boom cylinder ‘head’ pressure Measurement Voltage 侑 (Results / Symptoms) 1. Monitor – Boom cylinder ‘head’ press. display failure 2. Control Function – No Boom pressure calibration function operation, workload measurement sys. operation failure (Checking list) 1. CN-58B (#29) – CD-80 (B) Checking Open/Short 2. CN-58A (#11) – CD-80 (A) Checking Open/Short 3. CN-58B (#25) – CD-80 (C) Checking Open/Short