volvo — MID 144 PID 91 Accelerator Pedal Position (Percentage)

Group 28 Troubleshooting MID 144 PID 91 Accelerator Pedal Position (Percentage) 112 Type of fault: FMI Description: Fault Condition: Possible Symptoms: Possible Cause:

FMI 3 • Voltage above normal, or shorted to high source • Abnormally high voltage • Engine will not supply requested fuel to engine • APP harness shorted high • Faulty APP sensor FMI 4 • Voltage below normal, or shorted to low source • Abnormally low voltage • Engine will not supply requested fuel to engine • APP harness shorted low • Faulty APP sensor FMI 5 • Current below normal or open circuit • Abnormally low current • Input is not correct compared to IVS 1 & IVS 2 • Engine will not supply requested fuel increase • Faulty APP sensor FMI 6 • Current above normal or grounded circuit • Abnormally high current • Input is not correct compared to IVS 1 & IVS 2 • Engine will not supply requested fuel increase • Faulty APP sensor FMI 14 • Special Instructions • Supply error from PPID 72 • Supply error • Engine will not supply requested fuel increase • Faulty APP sensor harness