volvo — MID 128 SID 27 Variable Geometry Turbocharger

Group 28 Troubleshooting MID 128 SID 27 Variable Geometry Turbocharger 49 Type of fault: FMI Description: Fault Condition: Possible Symptoms: Possible Cause:

FMI 2 • Data erratic, intermittent or incorrect • Smart remote actuator has not seen a valid command on CAN2 • Incorrect data • Low boost • Low power • Nozzle opens • Smoke from engine • Disturbance on CAN2 data lines FMI 4 • Voltage below normal, or shorted to low source • Short to ground • Nozzle will open resulting in low power and low boost • SRA will continue to attempt and maintain target nozzle position • Faulty SRA VGT connector • Faulty SRA VGT harness • Low battery voltage FMI 7 • Mechanical system not responding or out of adjustment • Mechanical problem with the VGT SRA • Low boost and smoke • Possible engine derate • Power loss in some cases when actuator motor has been disabled • Actuator motor effort is temporarily limited to prevent overheating • Restrictions detected when running learn sequence • SRA is slow to follow commands • SRA position is not tracking command FMI 9 • Abnormal update rate • Data from the SRA has been missing for 2-seconds • Engine derated (major) • EGR valve closed • Data line harness • No supply to VGT actuator • VGT actuator • VGT SRA connector FMI 13 • Out of calibration • Failed self- calibration • N/A • Smart remote actuator