volvo — MID 130 PID 32 Split Cylinder, Position

Group 28 Troubleshooting MID 130 PID 32 Split Cylinder, Position 58 Type of fault: FMI Description: Fault Condition: Possible Symptoms: Possible Cause: FMI 3 • Voltage above normal, or shorted to high source • Status from ASIC is short circuit to U-BATT • Slow gear changes • Yellow lamp is sent • N/A FMI 5 • Current below normal or open circuit • Status from ASIC is open circuit • Yellow lamp is sent • Slow gear changes • N/A FMI 6 • Current above normal or grounded circuit • Status from ASIC is short circuit to ground • Yellow lamp is sent • Slow gear changes • N/A FMI 13 • Calibration value out of range • The checksum in NVRAM is not correct or, the sensor has not been calibrated.

• Yellow lamp is sent • Cranking is inhibited • Engine cannot start • N/A