GROUP 5 FAULT CODES GROUP 5 FAULT CODES 1. MACHINE FAULT CODE 1.
MACHINE FAULT CODE 4-41 Fault code Description HCESPN FMI 101 3 Hydraulic oil temperature sensor circuit - voltage above normal or shorted to high source (or open circuit) 4 Hydraulic oil temperature sensor circuit - voltage below normal or shorted to low source 105 0 Working pressure sensor data above normal range (or open circuit) 1 Working pressure sensor data below normal range 2 Working pressure sensor data error 4 Working pressure sensor circuit - voltage below normal, or shorted to low source 108 0 Travel oil pressure sensor data above normal range (or open circuit) 1 Travel oil pressure sensor data below normal range 2 Travel oil pressure sensor data error 4 Travel oil pressure sensor circuit - voltage below normal or shorted to low source 122 0 Overload pressure sensor data above normal range (or open circuit) 1 Overload pressure sensor data below normal range 2 Overload pressure sensor data error 3 Overload pressure sensor circuit - voltage below normal or shorted to low source 301 3 Fuel level sensor circuit - voltage above normal or shorted to high source (or open circuit) 4 Fuel level sensor circuit - voltage below normal or shorted to low source 503 0 Brake pressure sensor data above normal range (or open circuit) 1 Brake pressure sensor data below normal range 2 Brake pressure sensor data error 4 Brake pressure sensor data - voltage below normal or shorted to low source 505 0 Working brake pressure sensor data above normal range (or open circuit) 1 Working brake pressure sensor data below normal range 2 Working brake pressure sensor data error 4 Working brake pressure sensor circuit - voltage below normal, or shorted to low source 530 0 Travel fwd pilot pressure sensor data above normal range (or open circuit) 1 Travel fwd pilot pressure sensor data below normal range 2 Travel fwd pilot pressure sensor data error 4 Travel fwd pilot pressure sensor circuit - voltage below normal, or shorted to low source 14 Travel fwd pilot pressure sensor circuit - special instructions 16 Travel fwd pilot pressure sensor circuit - voltage valid but above normal operational range 701 4 Hour meter circuit - voltage below normal, or shorted to low source 705 0 MCU input voltage high 1 MCU input voltage low 707 1 Alternator node I voltage low (or open circuit) 714 3 Acc.
dial circuit - voltage above normal, or shorted to high source (or open circuit) 4 Acc. dial circuit - voltage below normal, or shorted to low source 840 2 Cluster communication data error 841 2 ECM communication data error IDSP Water in fuel warning Lo bat Low battery warning