hyundai R60WVS Pro — 3. ELECTRICAL SYSTEM

GROUP 3 ELECTRICAL SYSTEM GROUP 3 ELECTRICAL SYSTEM 1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT 1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT APPEAR APPEAR · Before disconnecting the connector, always turn the starting switch OFF. · Before carrying out below procedure, check all the related connectors are properly inserted and short of fuse No.2 and No.7. · After checking, insert the disconnected connectors again immediately unless otherwise specified. Check voltage CLUSTER CN-56 5-23 YES Check voltage YES between CN-56 (2) and chassis NO Check voltage between CN-56 (1) and chassis Starting switch : ON Voltage :

10~12.5V NO Cause Remedy Defective cluster Disconnection in wiring harness or poor contact between CN-56 (2) and fuse No.7. Disconnection in wiring harness or poor contact between CN-56 (1) and fuse No.2 Replace Repair or replace (after clean) Repair or replace (after clean) YES 10 ~ 12.5V NO 0V POWER IG(12V) POWER 12V 2 1 NO.7 FUSE NO.2