Komatsu — 24.2.1 Check Clean, or Replace Air Cleaner Element

24. SERVICE PROCEDURE 3. Direct dry compressed air (less than 700 kPa (7 kgf/cm 2 , 100 psi)), to the element from inside along its folds, then direct it from outside along its folds and again from inside. 1) Remove one seal from the outer element whenever the outer element has been cleaned. 2) Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. 3) If the dust indicator displays red immediately after the outer element has been cleaned, replace both the inner and outer elements, even if the outer element has not been cleaned 6 times.

4) Check inner element mounting nut 4 for looseness and, if necessary, retighten. Tightening torque of mounting nut: 5.4 ± 0.5 N·m (0.55 ± 0.05 kgf·m, 4.0 ± 0.4 lbft) 5) Replace seal washer 5 or wing nut 2 , mounting nut 4 with new parts if they are broken. Tightening torque of mounting nut: 5.4 ± 0.5 N·m (0.55 ± 0.05 kgf·m, 4.0 ± 0.4 lbft)) 6) Remove evacuator valve 6 and clean with compressed air. After cleaning, reset the evacuator valve. NOTICE If small holes or thinner parts are found on element when it is checked with an electric bulb after cleaning and drying, replace the element. When cleaning the element, do not hit it or beat it against anything.

Do not use element whose folds or gasket or seal are damaged. AE063690 4. Install the cleaned element. Tightening torque of wing nut: 6.9 ± 1.0 N·m (0.7 ± 0.1 kgf·m, 5.1 ± 0.7 lbft) AE073060 5. Press the button of dust indicator 1 to return the red piston to its original position. 3-23