24. SERVICE PROCEDURE 24.9 EVERY 2000 HOURS SERVICE WARNING Always hang a warning tag on work equipment control lever 1 . Maintenance for every 50, 100, 250, 500 and 1000 hours should be carried out at the same time. 24.9.1 REPLACE HYDRAULIC TANK BREATHER ELEMENT WARNING The oil is at high temperature immediately after the machine has been operated. Wait for the oil to cool down before changing the oil. When removing the oil filler cap, turn it slowly to release the internal pressure, then remove it carefully. 1. Loosen bolt 2 at the top of the cap. 2. Remove the cap, then take out the element. 3. Coat the O-ring of the new element with grease, then install the element. 4.
Align the cap with the body and tighten the bolts. 3-60