STANDARD MAINTENANCE R.H. PPC VALVE R.H. PPC VALVE 1.5 Nm 39.2 4.9 Nm Unit: mm 40-14 SK714-5 SK815-5 1 44.14.9 Nm 3 Section A - A Section B - B 2 Section D - D 4 Section C - C Section E - E RKS00852 N° Check item Criteria Remedy Standard size Repair limit Replace springs. If there are damage or deformation Free installed x Øe Installed I length nstalled load Free length Installed load 1 Centering spring (for P3 and P4) 42.4x15.5 34 9.8 N – 9.2 N 2 Centering spring (for P1 and P2) 36.6x15.5 34 17.6 N – 16.5 N 3 Metering spring (for P3 and P4) 32.7x8.2 25.6 40.8 N – 39.4 N 4 Metering spring (for P1 and P2) 26.2x8.2 25.3 5.3 N – 4.3 N