Komatsu — L.H. PPC VALVE

STANDARD MAINTENANCE L.H. PPC VALVE L.H. PPC VALVE PATTERN CHANGE (OPTIONAL) 112.8 14.7 Nm 13.2 1.5 Nm 1 44.1 4.9 Nm 3 Section A - A Section B - B 39.2 4.9 Nm 2 Section D - D 3 Section C - C Section E - E RKS00853 Unit: mm 40-16 SK714-5 SK815-5 N° Check item Criteria Standard size Repair limit Free Installed Installed Free Installed installed x length load length load Øe Remedy Repair limit Replace springs.

If there are damage or deformation Installed length Installed load Free length Installed load 1 Centering spring (for Pout3 and Pout4) 35.5x15.5 34 9.8 N – 9.2 N 2 Centering spring (for Pout1 and Pout2) 36.6x15.5 34 17.6 N – 16.5 N 3 Metering spring (for P3 and P4 ) 26.2x8.2 25.3 5.3 N – 52.4 N